Introduction
For those who have been following my blog, you know that one of my hobbies is to collect and restore IBM AS/400 systems. I already restored a 9401-150 and I am always on the lookout for more different machines. So when I spotted a listing on LeBonCoin for an iSeries 810 with a disk array expansion for only 100 euros, I did not hesitate for a second.
What followed was not just a restoration. It was a months-long journey involving faulty disks, locked-out service tools, a SCSI disk imaging project, and a year-long hunt for original installation media. I learned the hard way that a broken disk array with mirroring was a pain to fix. But let me start from the beginning.
Finding the machine
In September 2024, a listing appeared on LeBonCoin for an IBM iSeries 810 (model 9406-810) located near Mayenne (53100) in France. The price was 100 euros.
The backstory of how this machine ended up for sale is fairly typical of how old enterprise hardware surfaces. The seller had bought a full 42U rack at an auction of seized assets from a company filing for bankruptcy. The company was FOG , a former industrial company based in Cosne-sur-Loire in FRANCE. The seller did not really know what the machine was. He just wanted to sell it (he bought the full 42U rack and then sold individual parts for higher prices).
The listing showed a 9406-810 with a 7116 Disk Unit Expansion physically attached to the right side of the main tower. Having a machine with its disk array extension still intact is quite rare. At 100 euros, this was too good to pass up.
The road trip
The machine was about two hours away by car. That meant a four-hour round trip. My partner, being the awesome person she is, agreed to come help me on this adventure. We folded the back seats of my car down and set off towards Mayenne.
According to the IBM specifications , the 9406-810 alone weighs 79.6 kg (175 lb) with the 7116 disk expansion attached to it. When we arrived, the seller helped us load the machine into the trunk. It fit, but barely.

Two hours later, we were home. And that is when the real fun began.
The 175 lbs staircase problem
The machine needed to go up to the first floor.
We went slowly and patiently, one step at a time, lifting this massive black cube up the staircase. At one point, the machine slipped and we almost dropped it. My partner could have been seriously hurt. We managed to catch it, but it was a genuine scare.
NOTE: Do not attempt this at home. Carrying 175 lbs of vintage server hardware up a narrow staircase with two people is genuinely dangerous. Get professional movers, or at the very least, more people to help. We were… let’s say… professionals.
Once the machine was safely on the first floor, I could finally take a proper look at it.
Cleaning the machine
I opened the machine up to inspect the interior. There was some dust inside, but honestly not as much as I have seen in other machines. The exterior was in decent shape as well. I dusted off all the components, cleaned the fans, and made sure all the PCI cards and connectors were free of debris.
After a thorough cleaning, the machine looked great. Time to try powering it on.
First boot: the disk array nightmare
SRC 27579021
I connected my IBM InfoWindow II 3488 Twinax console, plugged in the power cable, and pressed the white power button on the control panel. The fans spun up. The control panel lit up. For a moment, things were looking good.
Then the system halted with the following SRC (System Reference Code) on the control panel display:
27579021
“Array not functional due to present hardware configuration. Failing item: IOPIP 20.”
The disk array was broken.
Three faulty disks out of ten
The machine contained 10 IBM 4326 35.4 GB SCSI disk drives spread across the main tower and the 7116 disk expansion. Out of these 10 drives, three were faulty. One was completely dead, located in Disk Array A (main tower) slot 3. Two others had read errors at various locations.
Trying every IPL combination
I tried everything. Normal mode. Manual mode. Side A. Side B. Every single combination of IPL modes and types I could think of. It did not matter. Every attempt ended with the same 27579021 SRC code staring back at me from the control panel. The faulty disks were a hard blocker. The system refused to go any further.
Getting into DST
The QSECOFR problem
On a normal IPL, the system would not even reach DST (Dedicated Service Tools) because the disk array failure happened before that stage. Without DST access, I could not diagnose or reconfigure the disks. I was stuck.
The breakthrough: IPL side D in Manual mode
After a lot of research, I found the way forward. I switched the control panel to IPL side D in Manual mode. This tells the machine to boot from the CD drive instead of the internal disks. I inserted the I_BASE_01 CD containing the System Licensed Internal Code (SLIC) for V5R4 and powered on.
This time, the system booted from the CD and dropped me into DST. Finally, I could see what was going on with the disks. However, because I was running from side D (removable media), I could not make permanent configuration changes such as resetting the DST password. This was essentially a read-only diagnostic session.
It was progress, but the road ahead was still long.
Preserving the data: building a SCSI disk dump station
Before touching anything on the disk configuration, I wanted to preserve whatever data was still readable. This machine came from a real company. There might be interesting historical data on those drives.
I built a SCSI disk dump station from an old PC equipped with a SCSI controller. I pulled each working disk from the machine one by one and created full disk images on the station. This gave me a complete snapshot of the machine’s data before I attempted any repairs or reinstallation. Having these images as a safety net was essential for what came next.
Months of experiments, and a difficult decision
I spent months trying to recover the disk array. I experimented with different configurations in DST, tried various recovery procedures, and explored every option I could find in IBM’s documentation. None of it worked. The DASD configuration was completely broken. The combination of one dead drive and two degraded drives had corrupted the array beyond what could be repaired in place.
I came to a difficult decision: I would have to do a full OS reinstallation.
Replacing the faulty disks
First, I replaced the three faulty drives with working IBM 4326 35.4 GB SCSI drives. Finding exact replacements took some effort, but using the same drive model was necessary to maintain compatibility with the disk array controller.
The year-long hunt for installation media
Reinstalling OS/400 on these machines is not as simple as downloading an ISO. You need the original installation CDs that are compatible with your specific machine model. On top of that, you need valid licence keys for the operating system. Without the licence keys, the machine will lock itself after 70 days and require yet another complete reinstallation.
I searched for over a year. I monitored eBay, forums, and various online marketplaces, week after week. Eventually, I found a compatible set of OS/400 V5R4 installation CDs on eBay. When that package arrived in the mail, I was incredibly relieved.
A fresh start: OS/400 V5R4M0
With the replacement disks installed and the original media finally in hand, I performed a fresh installation of OS/400 V5R4M0. The IPL from the installation CDs went smoothly. The disk array was rebuilt with the new drives. The system came up to a clean sign-on screen.
After months of debugging, experiments, and waiting, seeing that green-on-black OS/400 prompt appear on the InfoWindow II was one of the most satisfying moments of this entire project.
RAM upgrade
While I had the machine open for the disk replacements, I also upgraded all the main storage (RAM) to 8 x 1 GB modules, totalling 8 GB. This is the maximum supported configuration for the 9406-810. More memory means better performance for the development workloads I plan to run on this machine.
Console setup
Throughout the entire debugging and restoration process, I used the IBM InfoWindow II 3488 Twinax console to interact with the machine. This is the same console I cleaned and repaired for my previous AS/400 restoration.
IBM AS/400s are legendary mainframes still present in many companies. In this article I detail how I completely restored an AS/400 9401-150 server.
Current state
This machine is now fully operational, running OS/400 V5R4M0 with 8 GB of RAM and a healthy disk array. It has become my main AS/400 development environment while I work on getting other machines in my collection to a working state.
From a dusty 100 euro LeBonCoin find to a fully functional iSeries development server. It took over a year, a lot of patience, and a few close calls on the staircase. But it was absolutely worth it.